User's Manual

Property Definition
Minimum Warning Threshold Exceeded—The
temperature of the enclosure has dropped
below the minimum warning threshold.
Maximum Warning Threshold Exceeded—The
temperature of the enclosure has exceeded
above the maximum warning threshold.
Missing — The temperature probe is not
present in the enclosure.
Inactive — The temperature probe is present in
the enclosure, but the EMM that it monitors is
not installed.
Reading Displays the current temperature of the enclosure
as reported by the temperature probe.
Warning Threshold The Minimum and Maximum properties indicate
the temperatures currently set for the Warning
threshold.
Failure Threshold The Minimum and Maximum properties indicate
the temperatures currently set for the Failure
threshold.
Related Links
Enclosure Temperature Probes
Checking The Temperature Of The Enclosure
Setting The Temperature Probe Values
Enclosure Management Modules (EMMs)
The Enclosure Management Modules (EMMs) that are installed in the enclosure are displayed under the
EMMs object in the tree view. You can select the EMMs object to view the individual EMM modules and
their status information.
The enclosure may contain one or more EMMs. The EMM modules monitor components of the
enclosure. These components include:
Fans
Power supplies
Temperature probes
The insertion or removal of a physical disk
The LEDs on the enclosure
When the alarm on the enclosure is enabled, the EMM activates the alarm when certain conditions occur.
For more information on enabling the alarm and the conditions that activate the alarm, see Enabling The
Enclosure Alarm. For more information on EMMs, see the enclosure hardware documentation.
All EMM modules in the enclosure should have the same version of firmware. You can view the properties
of each individual EMM module to verify the firmware version.
Verifying The EMM Firmware Version Of The Enclosure
Does my controller support this feature? See Supported Features.
The firmware for the EMM must be at the same level as that of the enclosure. The status of the EMMs is
displayed as degraded if there is a mismatch between the EMM firmware.
108