SNMP Reference Guide

TrapID Description Severity
2715393 Battery Failure Critical
2715521 Battery Failure Cleared Information
487169 CPU Thermal Trip (Over
Temperature Shutdown)
Critical
487297 CPU Thermal Trip (Over
Temperature Shutdown) Cleared
Information
487168 CPU Internal Error Critical
487296 CPU Internal Error
Cleared
Information
487173 CPU Configuration Error Critical
487301 CPU Configuration Error Cleared Information
487175 CPU Presence (Processor
Presence detected)
Information
487303 CPU Not Present (Processor Not
Present)
Critical
487170 CPU BIST (Built In Self Test)
Failure
Critical
487298 CPU BIST (Built In Self Test)
Failure Cleared
Information
487176 CPU Disabled (Processor
Disabled)
Critical
487304 CPU Enabled (Processor Enabled) Information
487178 CPU Throttle (Processor Speed
Reduced)
Warning
487306 CPU Throttle Cleared (Normal
Processor Speed)
Information
527106 Power Supply Redundancy
Degraded
Warning
527105 Power Supply Redundancy Lost Critical
527104 Power Supply Redundancy has
returned to Normal
Information
552704 Power Supply Inserted Information
552832 Power Supply Removed Warning
552705 Power Supply Failure Critical
552833 Power Supply Failure Cleared Information
552706 Power Supply Warning Warning
552834 Power Supply Warning Cleared Information
519