SNMP Reference Guide

drsCASSPrevStatus, drsCASSChangeTime and drsCAMessage. The trap variables are defined in the Dell
Remote Access Controller Out-of-Band Group section.
Table 1979. PowerEdge M1000e CMC traps
TrapID Name Description Severity Category
2000 alertCMCTestTrap CMC has generated a
test trap.
Informational Error Events
2002 alertCMCNormalTrap CMC reported a return-
to-normal or
informational event.
Normal Error Events
2003 alertCMCWarningTra
p
CMC reported a warning
event.
Warning Error Events
2004 alertCMCCriticalTrap CMC reported a critical
event.
Critical Error Events
2005 alertCMCNonRecove
rableTrap
CMC reported a
catastrophic event.
Non-Recoverable Error Events
PowerEdge VRTX CMC Traps
This section defines the traps that are generated by the SNMP agent of the PowerEdge VRTX CMC . All of
the enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID
1.3.6.1.4.1.674.10892.2.21 and are sent with the following trap variables: drsCA2MessageID,
drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName,
drsProductChassisLocation, drsChassisServiceTag and drsGlobalCurrStatus. The trap variables are defined
in the Dell Remote Access Controller Out-of-Band Group section.
System Trap Group
The System Trap Group contains traps that fall under the System event category.
Table 1980. Amperage Probe Traps
TrapID Description Category SubCategory Severity
alert2AmperageProbeNormal
2179 Current sensor reading is
within range.
Status Events Amperage Information
al
alert2AmperageProbeWarning
2178 Current sensor has detected
a warning value.
Status Events Amperage Minor
alert2AmperageProbeFailure
2177 Current sensor has detected
a failure value.
Error Events Amperage Critical
508