SNMP Reference Guide
Access Read-only
Table 1556. Array Disk Name
Name
arrayDiskName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2
Description Identifies the name of the array disk as represented in Storage
Management.
Syntax DisplayString
Access Read-only
Table 1557. Array Disk Vendor
Name
arrayDiskVendor
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.3
Description The array disk's manufacturer's name.
Syntax DisplayString
Access Read-only
Table 1558. Array Disk State
Name
arrayDiskState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.4
Description Identifies the current state of the array disk.
Possible states:
0: Unknown
1: Ready - Available for use, but no RAID configuration has been
assigned.
2: Failed - Not operational.
3: Online - Operational. RAID configuration has been assigned.
4: Offline - The drive is not available to the RAID controller.
6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed
disk.
7: Recovering - Refers to state of recovering from bad blocks on disks.
11: Removed - Indicates that array disk has been removed.
13: Non-RAID - Indicates that array disk is not a RAID capable disk.
14: Not Ready - Applicable for PCIeSSD devices indicating that the
device is in locked state.
15: Resynching - Indicates one of the following types of disk operations:
Transform Type, Reconfiguration, and Check Consistency.
22: Replacing - Indicates copyback operation is in progress.
24: Rebuild
25: No Media - CD-ROM or removable disk has no media.
26: Formatting - In the process of formatting.
28: Diagnostics - Diagnostics are running.
407