SNMP Reference Guide

For example, systemStatePowerSupplyStatusCombined provides the rolled up status of all power
supplies for the chassis.
The variables in List 2 provide the health status of each component of the corresponding subsystem.
Each octet of the value represents a component. If a power supply fails, the corresponding entry in
systemStatePowerSupplyStatusDetails, systemStatePowerSupplyStatusCombined,
systemStateChassisStatus and systemStateGlobalSystemStatus transitions to critical.
List 1
Variables that provide rolled-up health status for all components in associated subsystem in chassis:
systemStatePowerSupplyStatusCombined
systemStateVoltageStatusCombined
systemStateAmperageStatusCombined
systemStateCoolingDeviceStatusCombined
systemStateTemperatureStatusCombined
systemStateMemoryDeviceStatusCombined
systemStateChassisIntrusionStatusCombined
systemStateACPowerCordStatusCombined
systemStateEventLogStatus
systemStatePowerUnitStatusCombined
systemStateCoolingUnitStatusCombined
systemStateACPowerSwitchStatusCombined
systemStateRedundantMemoryUnitStatusCombined
systemStateProcessorDeviceStatusCombined
systemStateBatteryStatusCombined
systemStateSDCardUnitStatusCombined
systemStateSDCardDeviceStatusCombined
List 2
Variables that provide health status of each component in associated subsystem in chassis:
systemStatePowerSupplyStatusDetails
systemStateVoltageStatusDetails
systemStateAmperageStatusDetails
systemStateCoolingDeviceStatusDetails
systemStateTemperatureStatusDetails
systemStateMemoryDeviceStatusDetails
systemStateChassisIntrusionStatusDetails
systemStateACPowerCordStatusDetails
systemStatePowerUnitStatusList
systemStateCoolingUnitStatusList
systemStateACPowerSwitchStatusList
systemStateRedundantMemoryUnitStatusList
systemStateProcessorDeviceStatusList
systemStateBatteryStatusList
29