SNMP Reference Guide

nonRedundant(1)
The AC power switch is not expecting redundancy.
redundant(2)
The AC power switch is expecting redundancy.
Table 471. AC Power Cord State Capabilities
Variable Name: DellACPowerCordStateCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
The AC power cord’s capabilities are unknown.
onlineCapable(2)
The AC power cord can be disabled (offline) or
enabled (online).
notReadyCapable(4)
The AC power cord’s capabilities are not ready.
Table 472. AC Power Cord State Settings
Variable Name: DellACPowerCordStateSettings
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
The AC power cord’s state is unknown.
online(2)
The AC power cord’s state is disabled (offline) 0 or
enabled (online) 1.
notReady(4)
The AC power cord’s state is not ready.
acPowerCordHasPower (8)
The AC power cord has power.
acPowerCordIsActive Source(16)
The AC power cord is the active source of AC
power.
Table 473. Battery Reading
Variable Name: DellBatteryReading
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
predictiveFailure(1)
Battery sensor detects predictive failure.
failed(2)
Battery has failed.
presenceDetected(4)
Battery presence is detected.
Table 474. Power Cap Capabilities
Variable Name: DellPowerCapCapabilities
Data Type: Integer
134