Release Notes

for the Server Administrator to display the updated BIOS settings properly.
If you import an invalid root certificate into Server Administrator, using "Preferences-
> General Settings-> Web Server-> X.509 Certificate", and try to log on to the
application
after restarting the Web server, a blank page is displayed. To fix this issue,
restore your original "keystore.db" file before importing a valid root certificate. To
restore the
"keystore.db" file, use both the basic operating system commands and the Server
Administrator Command Line Instrumentation (CLI).
Perform the following steps from your operating system command line:
o
Type: omconfig system webserver action=stop
o
Locate the "keystore.db.bak" file. The default path is "C:\program
files\dell\SysMgt\apache-tomcat\conf".
o
Copy "keystore.db.bak" to "keystore.db".
o
Type: omconfig system webserver action=start
A temperature drop below a minimum failure threshold does not cause a system
reset
even if this alert action is set.
Clicking the "Back" and "Refresh" buttons on the browser may not display the correct
page
with respect to the Server Administrator component tree, tabs, tab menus, or help,
as
Server Administrator has been designed with limited functionality to reduce
overhead. Full feature capabilities of the Web browser such as "Back", "Refresh", and "Open
in New
Window" may not be supported.
Selecting the boot sequence under the BIOS "Setup" tab does not re-enable boot devices
that have been disabled in the System Setup Program, earlier.
The links on the Server Administrator home page may not work after repeated
random
clicking. To resolve this issue, refresh the browser by pressing <F5> or click
the browser
"Refresh" button.
All unsecured HTTP requests to Server Administrator receive an invalid response. Server
Administrator runs only one instance of the Web server, which is secure. Make all
connections through https://<ip address> : <port number>. Any "http://<ip address>:
<port
number>" request for connection with the server receives an invalid response.
If the browser used with Server Administrator does not display a page or perform an
action, make sure that the browser is in online mode. To go online, perform the
following:
o
In Internet Explorer, on the menu bar, click "File" and clear the "Work Offline"
option. When "Work Offline" is selected, a check mark is displayed to the left
of the option on the "File" menu.
If Internet Explorer prompts you to "Work Offline", "Connect", or "Try Again", always select
"Connect" or "Try Again". Do not select "Work Offline".
While setting dates in the "Asset Information" section of the Server Administrator
home
page, the current time is appended to the date. While setting dates with the CLI,
the
appended time is noon.
On some systems, temperature probe values and settings are only supported for whole
degrees, not tenths of a degree. On those systems, setting a fractional value for the
minimum warning temperature threshold results in the set value being rounded off to
the
next whole number value. This behavior may cause the minimum warning
threshold to
have the same value as the minimum failure threshold.
If you close the browser using the "Close" button on the browser or log off from the
operating system, the Server Administrator session is not terminated. This session is listed
in the Session Management page until the session time out occurs, or DSM SA connection