Release Notes
applicable:
On systems running
Windows:
o
Delete the file keystore.db at <installed
directory>\Dell\SysMgt\apache-
tomcat\conf\
o
Rename the file keystore.db.bak at <installed
directory>\Dell\SysMgt\apache-
tomcat\conf\to keystore.db
On systems running Linux:
•
For 32-bit OS
o
Delete the keystore.db file at
/opt/dell/srvadmin/lib/openmanage/apache-
tomcat/conf
o
Rename the keystore.db.bak at
/opt/dell/srvadmin/lib/openmanage/apache-
tomcat/conf to
keystore.db
•
For 64-bit OS
o
Delete the keystore.db file at
/opt/dell/srvadmin/lib64/openmanage/apache-
tomcat/conf
o
Rename the keystore.db.bak at
/opt/dell/srvadmin/lib64/openmanage/apache-tomcat/conf to
keystore.db
3.
Start the Web server.
•
BITS078118: On 12G systems with specific versions of iDRAC, you cannot set the
platform
event alert actions (reboot, shut down, and so on) through Server
Administrator. Set the
alert actions for the events through iDRAC GUI.
•
BITS129426: On R220 systems with single CPU, Server Administrator does not display
the CPU status message on CLI and GUI.
•
BITS130401: On 12G systems, you cannot set the BIOS setup password from the GUI.
Use
the CLI to set the password.
Issues for Server Administrator Running on All Microsoft Windows Operating Systems
•
Execute all Server Administrator CLI commands from a 32-bit Windows command
prompt.
You can access the 32-bit command prompt by clicking "Start-> Programs->
Accessories-> Command Prompt" or by clicking "Start-> Run" and then typing
"cmd.exe". Attempts to run
the CLI commands from the DOS command
"command.com" may generate unpredictable
results.
•
The DSM Server Administrator Connection Service may hang on system startup if both
Oracle and VERITAS Backup Exec are installed on the system. To manually start the DSM
Server Administrator Connection Service on a system running Windows, click "Start->
Programs-> Administrative Tools-> Service", right-click "DSM Server Administrator
Connections Services" and select "Start".
•
You may not have appropriate privileges on the Server Administrator GUI if you:
o
Belong to an Active Directory group that is part of another group.
o
Try to launch Server Administrator using the desktop icon when single
sign-
on is enabled.
•
Broadcom architecture has a split driver implementation - evbdx.sys and bxnd60x.sys.
o
evbdx.sys is the Virtual Bus Driver (VBD); also called the Base Driver
o
bxnd60x.sys is the driver for the Broadcom NDIS device.
Microsoft Device Manager reports both the drivers, but Server Administrator displays only
the driver details specific to the VBD device.
•
BITS080169: Documentation for Power Supply alerts mentions only AC power supply,
but
the alerts are valid for both AC and DC power supplies.