Reference Guide

name=value pair 1 Description
uncorrectable memory event. In the mirror mode,
the operating system does not switch back to the
original module until the system reboot.
disabled: Indicates that the system is not to use
other available memory modules if uncorrectable
memory events are detected.
raid5: Method of system memory configuration.
This is logically similar to the RAID-5 mode used in
hard drive storage systems. This memory mode
provides an extra level of memory checking and
error recovery at the expense of some memory
capacity. The RAID mode supported is RAID level 5
striping with rotational parity.
dddc: The dddc mode enables double device data
correction. This ensures data availability after hard
failure of x4 DRAM.
opmode=mirror | optimizer | advecc
mirror: Switches the systems to a mirrored copy of
the memory if the failing module has an
uncorrectable memory event. In the mirror mode,
the operating system does not switch back to the
original module until the system reboots.
optimizer: Enables the DRAM controllers to
operate independently in 64-bit mode and provide
optimized memory performance.
advanced ECC (advecc): Enables the two DRAM
controllers to combine in 128-bit mode and
provide optimized reliability. Memory that are not
teamed by the controllers is not reported to the
operating system.
Omconfig Chassis Pwrmanagement Or Omconfig Mainsystem
Pwrmanagement
Use the omconfig chassis pwrmanagement or omconfig mainsystem pwrmanagement command to
configure power cap and manage profiles that control power utilization.
NOTE: This command is valid only on systems prior to PowerEdge 12G systems.
The following table displays the valid parameters for the command:
Table 28. Valid Parameters Of Omconfig Chassis Pwrmanagement Or Omconfig Mainsystem
Pwrmanagement
name=value pair 1 name=value pair 2 Description
config=budget cap=<value>
Sets the threshold value for
power budget.
88