Reference Guide
or
omreport mainsystem temps index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays a summary
of status, readings, and thresholds set for any temperature probes that are present on the system. If you
specify the index, Server Administrator displays the summary for a specific temperature probe.
Omreport Chassis Volts Or Omreport Mainsystem Volts
Use the omreport chassis volts or omreport mainsystem volts command to view properties of the
system’s voltage probes. Type:
omreport chassis volts index=n
or
omreport mainsystem volts index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays a summary
of status, readings, and thresholds set for any voltage probes that are present on the system. If you
specify the index, Server Administrator displays a summary for a specific voltage probe.
Omreport Licenses
Use the omreport licenses command to view the digital licenses of the hardware devices installed on the
system. Type:
omreport licenses
The following is an example output from the omreport licenses command:
Device Index : 0
Device Status : Ok
Device : iDRAC7
Device Description : iDRAC
Device ID : xxxx
License Index : 0
Description : iDRAC7 Enterprise Evaluation License
Status : OK
Recommended Action : N/A
License Type : Evaluation
EntitlementID : xxxx
Expiry Date : yyyy-mm-dd hh:mm:ss
45