Reference Guide

Depending on the system’s configuration, you may notice the following output:
Index : 0
Chassis Name : Main System Chassis
Host Name : WIN-27C02UQFV6L
iDRAC7 Version : 1.00
Chassis Model : PowerEdge R720
Chassis Lock : Present
Chassis Service Tag : 7654321
Express Service Code : 15608862073
Chassis Asset Tag : c
Omreport Chassis Intrusion
Use the omreport chassis intrusion command to find out whether the cover of the system is open or not.
Server Administrator tracks chassis intrusion events because intrusions may indicate an attempt to steal a
system component, or to perform unauthorized maintenance on the system. Type:
omreport chassis intrusion
A message that resembles the following is displayed:
Intrusion Information
Health : Ok
Index : 0
Status : OK
Probe Name : Intrusion
State : Chassis is closed
Omreport Chassis Leds Or Omreport Mainsystem Leds
Use the omreport chassis leds or omreport mainsystem leds command to find out whether clear hard
drive fault is supported and what severity level lights up the LED. Type:
omreport chassis leds index=n
or
omreport mainsystem leds index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays a summary
of LED information for chassis 0. If you specify the index, Server Administrator displays a summary for a
specific chassis.
The following is an example output: