Reference Guide

Description Disables smart thermal shutdown for all controllers.
Syntax
omconfig storage globalinfo action=disablests
Example to Disable thermal shutdown. The omconfig command syntax for disabling
thermal shutdown does not require a controller or enclosure ID.
NOTE: You can use the omreport storage globalinfo command to
determine whether smart thermal shutdown is currently enabled or
disabled. The status of smart thermal shutdown is also displayed in the GUI
of Server Administrator. To locate this status, select the Storage object and
the Information/Configuration tab.
Example
omconfig storage globalinfo action=disablests
Omconfig Global Rescan Controller
Description Rescans all the controllers on the system. For more information about Global
Rescan Controller, see the Dell OpenManage Online Help.
Syntax
omconfig storage globalinfo action=globalrescan
Example to Do a global rescan of all controllers. The omconfig command syntax for
rescanning all controllers on the system does not require a controller or
enclosure ID.
NOTE: Global rescan is not supported on non-RAID SCSI and SAS
controllers. Reboot the system to make visible the configuration changes
on non-RAID SCSI controllers.
Example
omconfig storage globalinfo action=globalrescan
Omconfig Set Hot Spare Protection Policy
Table 118. Omconfig Set Hot Spare Protection Policy
Description Sets the hot spare protection policy for dedicated or global hot spares. For more
information, see the Dell OpenManage Server Administrator Storage
Management User’s Guide at dell.com/support/manuals.
Syntax
omconfig storage globalinfo action= setprotectionpolicies
type=dhs raid=<r1 | r5 | r6 | r10 | r50 | r60 | all>
hscount=<1-16> warnlevel=<0-3> includeghsinvdstate=<yes |
no>, where hscount is the number of hot spares assigned to the virtual disk and
warnlevel is the severity level you want to assign to the generated alert, if this
policy is violated. Use
hscount=0 warnlevel=0 to reset the dedicated hot
spare protection policy for the RAID level.
Example for Global hot spare protection policy
Example
omconfig storage globalinfo action=setprotectionpolicies
type=dhs hscount=1 warnlevel=1 includeghsinvdstate=yes
192