Reference Guide
NOTE: This command is not supported on SAS controllers.
Syntax
omconfig storage enclosure action=settempprobes controller=id
enclosure=<ENCLOSUREID> index=id minwarn=n maxwarn=n, where id
is the controller ID and the temperature probe ID. The <ENCLOSUREID> variable
specifies the enclosure.
In this syntax, n is a user-specified alphanumeric string.
Example to Set the temperature probe thresholds to 10 and 40 degree Celsius.
Example for SCSI,
SATA, and ATA
controllers
omconfig storage enclosure action=settempprobes controller=1
enclosure=2 index=3 minwarn=10 maxwarn=40
NOTE: Here, temperature probe 3 resides in the enclosure attached to
connector 2 on controller 1.
Omconfig Reset Temperature Probe Thresholds
Table 110. Omconfig Reset Temperature Probe Thresholds
Description Resets the minimum and maximum warning temperature thresholds back to
their default values.
NOTE: This command is not supported on SAS controllers.
Syntax
omconfig storage enclosure action=resettempprobes
controller=id enclosure=<ENCLOSUREID> index=id, where id is the
controller ID and the temperature probe ID. The <ENCLOSUREID> variable
specifies the enclosure.
In this syntax, n is a user-specified alphanumeric string.
Example to Reset the thresholds for temperature probe 3, residing in the enclosure attached
to connector 2 on controller 1, to the default values.
Example for SCSI,
SATA, and ATA
controllers
omconfig storage enclosure action=resettempprobes
controller=1 enclosure=2 index=3
NOTE: Here, temperature probe 3 resides in the enclosure attached to
connector 2 on controller 1.
Omconfig Set All Temperature Probe Thresholds
Table 111. Omconfig Set All Temperature Probe Thresholds
Description Sets the minimum and maximum warning temperature thresholds for all
temperature probes in the enclosure.
NOTE: This command is not supported on SCSI RAID controllers.
Syntax
omconfig storage enclosure action=setalltempprobes
controller=id enclosure=<ENCLOSUREID> minwarn=n maxwarn=n,
188