Reference Guide
Example to Enable the alarm on controller 1.
Example
omconfig storage controller action=enablealarm controller=1
Omconfig Disable Controller Alarm
Description Disables the controller alarm. For more information, see the Dell OpenManage
Online Help .
Syntax omconfig storage controller action=enablealarm controller=id,
where id is the controller ID as reported by the omreport storage controller
command.
Example to Disable the alarm on controller 1.
Example
omconfig storage controller action=disablealarm controller=1
Omconfig Quiet Controller Alarm
Table 89. omconfig Quiet Controller Alarm
Description Silences an activated controller alarm. For more information, see the Dell
OpenManage Online Help.
Syntax omconfig storage controller action=quietalarm controller=id,
where id is the controller ID as reported by the omreport storage controller
command.
Example to Quiet the alarm on controller 1.
Example
omconfig storage controller action=quietalarm controller=1
omconfig Test Controller Alarm
Table 90. omconfig Test Controller Alarm
Description Tests the functionality of the controller alarm. The alarm sounds for about two
seconds. For more information, see Dell OpenManage Online Help.
Syntax omconfig storage controller action=testalarm controller=id ,
where id is the controller ID as reported by the omreport storage controller
command.
Example to Test the alarm on controller 1.
Example
omconfig storage controller action=testalarm controller=1
169