Reference Guide

Required Command Levels
(1, 2, 3)
Optional name=value pairs
NOTE: Specify spinupstarttime and spinuptimeinterval only when you
set spindownconfigureddrives=enabled.
action=setpatrolreadmode controller=id mode=<manual | auto | disable>
action=startpatrolread controller=id
action=stoppatrolread controller=id
action=createcachecade controller=id pdisk=<PDISKID> [name=<string>]
action=enablelkm controller=id keyid=<keyid> passphrase=<passphrase
string> [escrow=yes] [filepath=<Absolute path to the escrow file>]
NOTE: If you set escrow=yes, specify the escrow file path.
action=switchtolkm controller=id keyid=<keyid> passphrase=<passphrase
string> [escrow=yes] [filepath=<Absolute path to the escrow file>]
NOTE: If you set escrow=yes, specify the escrow file path.
action=rekeylkm controller=id
action=convertraidtononraid controller=id pdisk=<PDISKID>
action=convertnonraidtoraid controller=id pdisk=<PDISKID>
Omconfig Rescan Controller
Description Rescans a controller. For more information, see the Dell OpenManage Online
Help .
Syntax omconfig storage controller action=rescan controller=id, where
id is the controller ID as reported by the omreport storage controller command.
Example to Rescan controller 1.
Example
omconfig storage controller action=rescan controller=1
NOTE: The rescan controller is not supported on non-RAID SCSI and SAS
controllers. Reboot the system to make the configuration changes visible
on non-RAID SCSI controllers.
Omconfig Enable Controller Alarm
Description Enables the controller alarm. For more information, see the Dell OpenManage
Online Help .
Syntax omconfig storage controller action=enablealarm controller=id,
where id is the controller ID as reported by the omreport storage controller
command.
168