Reference Guide

Omconfig Export Reliability Log
Description
Exports log on a physical disk or the PCIe SSD
controller.
Syntax
omconfig storage pdisk
action=exportreliabilitylog
controller=id pdisk=<PDISKID>, where id is
the controller ID. The <PDISKID> variable specifies
the physical disk.
NOTE: To obtain these values, type omreport
storage controller to display the controller IDs
and then type omreport storage pdisk
controller=ID to display the IDs for the
physical disks attached to the controller.
Example to Export log on physical disk 3 on connector 0 of
controller 1. On a SAS controller, the physical disk
resides in enclosure 2.
Example for SAS controllers
omconfig storage pdisk
action=exportreliabilitylog
controller=1 pdisk=0:2:3
Omconfig Convert RAID To Non-RAID
Description
Converts RAID to non-RAID on a physical disk.
Syntax
omconfig storage pdisk
action=convertraidtononraid
controller=id pdisk=<PDISKID>, where id is
the controller ID. The <PDISKID> variable specifies
the physical disk.
NOTE: To obtain these values, type omreport
storage controller to display the controller IDs
and then type omreport storage pdisk
controller=ID to display the IDs for the
physical disks attached to the controller.
NOTE: To convert multiple RAID to non-RAID
on a given controller, use omconfig storage
controller action=convertraidtononraid
command. For more information, see
omconfig Convert Multiple RAID To Non-
RAID.
Example to Convert RAID to non-RAID on physical disk 3 on
connector 0 of controller 1. On a SAS controller,
the physical disk resides in enclosure 2.
154