Reference Guide
Example Shutdown Commands
To set the shutdown action to reboot, type:
omconfig system shutdown action=reboot
or
omconfig servermodule shutdown action=reboot
To bypass operating system shutdown before the system is powered off, type:
omconfig system shutdown action=reboot osfirst=false
or
omconfig servermodule shutdown action=reboot osfirst=false
Omconfig System Thrmshutdown Or Omconfig Servermodule
Thrmshutdown
Use the omconfig system thrmshutdown or omconfig servermodule thrmshutdown command to
configure a thermal shutdown action. You can configure the system for a thermal shutdown when a
temperature probe detects a temperature probe warning or failure event.
The following table displays the valid parameters for the command:
Table 49. Valid Parameters Of Thermal Shutdown
name=value pair Description
severity=disabled | warning |
failure
disabled: Disable thermal shutdown. An administrator must
intervene.
warning: Perform a shutdown when a temperature warning event is
detected. A warning event occurs when any temperature probe
inside a chassis reads a temperature (in degree Celsius) that exceeds
the maximum temperature warning threshold value.
failure: Perform a shutdown when a temperature failure event is
detected. A failure event occurs when any temperature probe inside
a chassis reads a temperature (in degree Celsius) that exceeds the
maximum temperature failure threshold value.
Example Thermal Shutdown Commands
To trigger a thermal shutdown when a temperature probe detects a failure event, type:
omconfig system thrmshutdown severity=failure
or
omconfig servermodule thrmshutdown severity=failure
To disable thermal shutdown so that an administrator has to initiate an omconfig system shutdown, type:
omconfig system thrmshutdown severity=disabled
or
omconfig servermodule thrmshutdown severity=disabled
118