Reference Guide

Command Result Description
servermodule events
type=<component name>
severity=none
Index
Index refers to the number of an event for a particular component. Index is an optional parameter. When
you omit the index parameter, events are configured for all components of the specified type, such as all
fans. For example, when a system contains more than one fan, you can enable or disable event
notification for a particular fan. An example command is as follows:
omconfig system events type=fan index=0 severity=critical
or
omconfig servermodule events type=fan index=0 severity=critical
As a result of the example command, Server Administrator sends an SNMP trap only when the first fan in
the system chassis (index 0) has reached critical fan RPMs.
Omconfig System Webserver Or Omconfig Servermodule Webserver
Use the omconfig system webserver or omconfig servermodule webserver command to start or stop the
Web server. The following table displays the valid parameters for the command.
Table 46. Valid Parameters Of Web Server Configuration
name=value pair Description
action=start Starts the Web server.
action=stop Stops the Web server.
action=restart Restarts the Web server.
Omconfig System Recovery Or Omconfig Servermodule Recovery
Use the omconfig system recovery or omconfig servermodule recovery command to set the action when
the operating system hangs or crashes. You can also set the number of seconds that must pass before
the system is considered to have a hung operating system. The following table lists the valid parameters
for the command
NOTE: The upper and lower limits for the timer are dependent on the system model and
configuration.
Table 47. Valid Parameters Of Omconfig System Recovery Or Omconfig Servermodule Recovery
name=value pair Description
action=none Takes no action when the operating system is hung or has crashed.
action=reboot Shuts down the operating system and initiates system startup, performing BIOS
checks, and reloading the operating system.
action=poweroff Turns off electrical power to the system.
116