Reference Guide

Table 42. Parameters For Alert Action Command
Action Description
action=disable Disables the SNMP alert.
action=enable Enables the SNMP alert.
action=none Takes no action when the system is hung or has crashed.
action=powercycle Turns off the electrical power to the system, pauses, turns the power on, and
reboots the system.
action=poweroff Turns off the electrical power to the system.
action=powerreduc
tion
Reduces the processor speed until the power consumption comes down and
reaches below the warning threshold. If the system power consumption stays
below the warning threshold, increases the processor speed.
NOTE: This action is applicable only for PowerEdge Rack and Tower systems
earlier than PowerEdge 11G systems.
action=reboot Forces the operating system to shut down and initiates system startup, performs
BIOS checks, and reloads the operating system.
Components And Events Of Platform Events
The following table lists the components and the events for which you can set platform events.
Components are listed in alphabetical order, except that warning events always precede failure events for
a component.
Table 43. Valid Parameters Of Omconfig System Platformevents
Event Name Description
alertsenable=true | false
true: Enables generation of platform event filter alerts.
false: Disables generation of platform event filter alerts.
NOTE: This setting is independent of the individual platform event
filter alert settings. For a platform event filter to generate an alert,
both the individual alert and the global event alert are enabled.
event=batterywarn Sets action or enables or disables alert generation when a battery
device detects that the battery is pending a failure condition.
event=batteryfail Sets action or enables or disables alert generation when a battery
device detects that the battery has failed.
event=discretevolt Sets action or enables or disables alert generation when a discrete
voltage probe detects that the voltage is too low for proper operation.
event=fanfail Sets action or enables or disables alert generation when a fan probe
detects that the fan is running too slow or not at all.
event=hardwarelogfail Enables or disables alert generation when a hardware log detects a
failure value.
event=intrusion Sets action or enables or disables alert generation when a chassis is
opened.
112