Reference Guide
所需命令级别(1、2、3) 可选“名称=值”对
action=clearforeignconfig controller=id
action=setpdiskpwrmanagement controller=id
spindownunconfigureddrives=<enabled/disabled>
spindownhotspares=<enabled/disabled>
spindownconfigureddrives=<enabled/disabled> idlec=<enabled/disabled>
spindowntimeinterval=<30 to 1440>(minutes)
spinupstarttime=<HH:MM:AM/PM> spinuptimeinterval=<1 to 24>(hours)
注: 仅在您设置 spindownconfigureddrives=enabled 时才能指定
spinupstarttime 和 spinuptimeinterval。
action=setpatrolreadmode controller=id mode=<manual | auto | disable>
action=startpatrolread controller=id
action=stoppatrolread controller=id
action=createcachecade controller=id pdisk=<PDISKID> [name=<string>]
action=enablelkm controller=id keyid=<keyid> passphrase=<passphrase
string> [escrow=yes] [filepath=<Absolute path to the escrow file>]
注: 如果设置 escrow=yes,请指定 escrow 文件路径。
action=switchtolkm controller=id keyid=<keyid> passphrase=<passphrase
string> [escrow=yes] [filepath=<Absolute path to the escrow file>]
注: 如果设置 escrow=yes,请指定 escrow 文件路径。
action=rekeylkm controller=id
action=convertraidtononraid controller=id pdisk=<PDISKID>
action=convertnonraidtoraid controller=id pdisk=<PDISKID>
Omconfig 重新扫描控制器
说明 重新扫描控制器。有关更多信息,请参阅 Dell OpenManage Online Help(Dell
OpenManage
联机帮助)。
语法 omconfig storage controller action=rescan controller=id,其中
id 是由 omreport storage controller 命令报告的控制器 ID。
例如, 重新扫描控制器 1。
示例
omconfig storage controller action=rescan controller=1
注: 重新扫描控制器在非 RAID SCSI 和 SAS 控制器上不受支持。重新引导系
统
,使配置更改在非 RAID SCSI 控制器上显示。
157