Command Line Interface Guide
Omconfig Chassis Remoteaccess Or Omconfig Mainsystem Remoteaccess
Use the omconfig chassis remoteaccess or omconfig mainsystem remoteaccesscommand to configure:
• Remote access on a local area network (LAN).
• The serial port for BMC or RAC, whichever is installed.
• The BMC or RAC on a serial over LAN connection.
• Terminal settings for the serial port.
• Advanced settings for a serial over LAN connection.
• Information on a BMC or RAC user.
• Information on IPv6 and IPv4 interfaces.
NOTE: Enter the user ID to configure user information.
Type:
omconfig chassis remoteaccess
or
omconfig mainsystem remoteaccess
The output of the omconfig chassis remoteaccess or omconfig mainsystem remoteaccess command
lists each of the available configurations. The following table displays the valid parameters:
Table 30. Valid Parameters Of Omconfig Chassis Remoteaccess Or Omconfig Mainsystem Remoteaccess
name=value pair 1
config=
name=value pair 2 Description
config=additional ipv4=enable | disable
enable: IPv4 stack to load on iDRAC.
disable: IPv4 stack to flush on iDRAC.
ipv6=enable | disable
enable: Enables IPv6 stack to load on iDRAC.
disable: Disables IPv6 stack to unload on
iDRAC.
NOTE: This option requires license to
enable or disable ipv6. If the appropriate
license is not installed or has expired, the
system displays an error message. For
more information, see Dell License
Manager at dell.com/
openmanagemanuals.
config=advsol characcuminterval=number
number: Sets the character accumulate
interval in 5 millisecond intervals.
charsendthreshold=number
number: Sets the number of characters. BMC
automatically sends a serial over LAN data
packet that contains the number of characters
as soon as this number of characters (or
greater) has been accepted from the
baseboard serial controller into the BMC.
enableipmi= true | false
true: Enables IPMI over LAN.
false: Disables IPMI over LAN.
enablenic=true | false
true: Enables DRAC NIC.
false: Disables DRAC NIC
91