Command Line Interface Guide
name=value pair Description
config=serial Reports serial port information for BMC or remote access.
config=serialoverla
n
Reports BMC/iDRAC or remote access information on a serial over LAN
connection.
config=terminalmo
de
Reports terminal mode settings for the serial port.
config=user Reports information on BMC/iDRAC or remote access users.
Omreport Chassis Removableflashmedia Or Omreport Mainsystem
Removableflashmedia
Use the omreport chassis removableflashmedia or omreport mainsystem removableflashmedia to view
the removable flash media details on the system along with its health status. Type:
omreport chassis removableflashmedia
or
omreport mainsystem removableflashmedia
Server Administrator displays a summary of the system’s removable flash media information.
NOTE: If the vFlash or SD card size is less than 1 GB, the size is displayed in MB.
Depending on the configuration of the system, you may notice the following output:
Removable Flash Media Information
Health : Critical
Internal Dual SD Module Redundancy : Critical
Attribute : Redundancy
Value : Lost
Internal SD Modules Status
Status : OK
Connector Name : System Board SD Status 1
State : Present
Storage Size : 512 MB
Status : OK
Connector Name : System Board SD Status 2
State : Present
Storage Size : 512 MB
VFlash Media Details
Connector Name : System Board SD Status 1
Type : vFlash SD Card
43