Command Line Interface Guide

Peak Reading : 2.5 A
NOTE: Power Management features are only available for PowerEdge systems that have hot-
swappable power supplies and not systems that have a fixed, non-redundant power supply installed.
Omreport Chassis Pwrsupplies Or Omreport Mainsystem Pwrsupplies
Use the omreport chassis pwrsupplies or omreport mainsystem pwrsupplies command to view properties
of the system’s power supplies. Type:
omreport chassis pwrsupplies
or
omreport mainsystem pwrsupplies
NOTE: To maintain consistency across the commands, the output format of this command has
changed. Change the user scripts as applicable.
For each power supply profile in the system, the values for the following fields are displayed:
Status
Location
Type
Rated Input Wattage (in Watts)
Maximum Output Wattage
Online Status
Power Monitoring Capable
Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess
Use the omreport chassis remoteaccess or omreport mainsystem remoteaccess command to view
general information on baseboard management controller or integrated Dell remote access controller
(BMC/iDRAC) and remote access controller if DRAC is installed. Type:
omreport chassis remoteaccess
or
omreport mainsystem remoteaccess
NOTE: To maintain consistency across the commands, the output format of this command and the
subsequent command levels has changed. So, you may have to change the user scripts as
applicable.
The output of the omreport chassis remoteaccess or omreport mainsystem remoteaccess command lists
each of the valid parameters as displayed in the following table:
Table 12. Valid Parameters Of Omreport Chassis Remoteaccess Or Omreport Mainsystem Remoteaccess
name=value pair Description
config=additional Reports the current state of IPv4 and IPv6 addresses on iDRAC.
config=advsol Reports advanced BMC/iDRAC or remote access information on a serial over local
area network (LAN) connection.
config=nic Reports BMC/iDRAC or remote access information for the LAN.
42