Command Line Interface Guide

Minimum Failure
Threshold
: 500RPM
Maximum Failure
Threshold
: 6000RPM
You can use a text editor to insert the time that each block of data was captured. In comparing the two
snapshots for fan probe 0, you can see that the second report shows several changes. The reading of fan
RPM has increased by 621 RPM but is still within normal range. Someone has raised the minimum
warning threshold by 200 RPM and has decreased the maximum warning threshold by 2000 RPM.
Selecting A Format For The CLI Command Output
You can specify a format for the CLI command results. The format determines how the command output
is displayed. If the command results are directed to a file, the format is captured by the file to which you
write the command results.
The available formats include:
List (lst)
Semicolon-separated values (ssv)
Table (tbl)
Custom delimited format (cdv)
The syntax for the formatting option is:
<command> -fmt <format option>
For example, type:
omreport system summary -fmt tbl
or
omreport servermodule summary -fmt tbl
where -fmt tbl specifies table format.
You can combine the formatting option with the option to direct output to a file. For example, type:
omreport system summary -fmt tbl -outa summary.txt
or
omreport servermodule summary -fmt tbl -outa summary.txt
where -fmt tbl specifies table format and -outa specifies that you append the command results to a file
named summary.txt .
List (lst)
The default format is lst or list format. Use this format when you want to optimize output for simple
readability. You need to specify a format for the command output only if you want a format other than
the lst format.
To see the following example command output in lst format, type:
omreport system summary
or
omreport servermodule summary
196