Command Line Interface Guide
Omconfig Battery Commands
The following table displays the omconfig command syntax required to execute battery tasks.
Table 114. Omconfig Battery Commands
Required Command
Levels (1, 2, 3)
Optional name=value pairs
omconfig storage
battery
action=startlearn controller=id battery=id
action=delaylearn controller=id battery=id days=d hours=h
omconfig Start Battery Learn Cycle
Table 115. Omconfig Start Battery Learn Cycle
Description Starts the battery learn cycle.
Syntax
omconfig storage battery action=startlearn controller=id
battery=id, where id is the controller ID and battery ID as reported by the
omreport command. To obtain this value, type omreport storage
controller
to display the controller IDs and then type omreport storage
battery controller=ID to display the ID for the controller battery.
Example to Start the learn cycle on controller 1.
Example
omconfig storage battery action=startlearn controller=1
battery=0
Omconfig Delay Battery Learn Cycle
Table 116. Omconfig Delay Battery Learn Cycle
Description Delays the battery learn cycle for a specified period of time. You can delay the
battery learn cycle for a maximum of seven days or 168 hours.
Syntax
omconfig storage battery action=delaylearn controller=id
battery=id days=d hours=h, where id is the controller ID and battery ID as
reported by the omreport command. To obtain this value, type omreport
storage controller
to display the controller IDs and then type omreport
storage battery controller=ID to display the ID for the controller
battery.
Example to Delay the learn cycle for three days and 12 hours on controller 1.
Example
omconfig storage battery action=delaylearn controller=1
battery=0 days=3 hours=12
Omconfig Global Commands
The following table displays the omconfig command syntax required to execute the global commands.
When executed, these commands apply to all controllers. These global commands also correspond to
the global tasks provided by the Storage tree view object’s Information/Configuration subtab.
184