Command Line Interface Guide

Command
omconfig chassis volts index=3 minwarnthresh=3.3000
Message
Error! Number with up to 3 digits after decimal point
expected, read 3.3000
The value given by the command specifies more than 3 digits
after the decimal point. A valid minimum warning threshold
value for volts contains up to 3 digits after the decimal
point.
Revised command
omconfig chassis volts index=3 minwarnthresh=3.300
When you type the revised command with three decimal points, you receive another error message:
Message
Error! This voltage probe min warning threshold must be
between 11.400 and 12.480.
Revised command
omconfig chassis volts index=3 minwarnthresh=11.500
Message
Voltage probe warning threshold(s) set successfully.
Scripting And Comparing Using CLI
The Server Administrator CLI allows administrators to write batch programs for the operating system. For
an enterprise with many systems, an administrator could write a configuration script that specifies the
warning thresholds for each major component of a system and also specifies a set of actions that the
administrator wants each system to take in case of a warning or failure event. In most critical cases, the
administrator could write a script so that the system shuts down to prevent damage. The administrator
could then distribute and execute the script to many managed systems at the same time. Such a scenario
facilitates configuring any number of new systems acquired by a company and makes implementation of
new system administration policies easier across many existing systems that require re-configuration.
A similar scenario is used to populate a large number of newly acquired systems with detailed asset
information. Much of the information are the same, such as the manufacturer or lessor of the system,
whether support for the system is outsourced, name of the company providing insurance for the system,
method of depreciation, and so on. Any variable that is common to all systems is scripted, sent to all
managed systems, and executed. Asset information that is unique to a system is scripted as a group and
sent to that managed node for execution. For example, a script could specify values for all unique
variables such as the owner, primary user phone number, asset tag, and so on. Scripts to populate unique
values would set all unique variables at once rather than one by one through the system's command line.
In many cases, the CLI allows a user with a very well-defined task in mind to retrieve information about
the system rapidly. If a user wants to review a comprehensive summary of all system components and
save that summary information to a file for comparison with later system states, the CLI is ideal.
Using CLI commands, administrators can write batch programs or scripts to execute at specific times.
When these programs are executed, they can capture reports on components of interest, such as fan
RPMs during periods of highest system usage compared with the same measurements at times of lowest
system usage. Command results are routed to a file for later analysis. Reports can help administrators
gain information that are used to adjust usage patterns, to justify purchasing new system resources, or to
focus on the health of a problem component.
Command Syntax Overview
Commands vary in complexity. The simplest command has only command level 1. The omhelp
command is a simple command. When you type omhelp, a list of the main CLI commands is displayed.