Command Line Interface Guide
Table 73. Omreport Enclosure Slot Occupancy Report Commands
Required Command Levels (1, 2,
3) and name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for
all enclosures attached to the
system.
controller=id
enclosure=<ENCLOSUREID>
info=pdslotreport, where id is the
controller number and
ENCLOSUREID is the enclosure
number. For example:
controller=0 enclosure=2
Displays the empty and occupied
slot details for the specified
enclosure.
NOTE: This command is not
supported on Blackplane,
SCSI, and SWRAID
controllers.
Omreport Battery Status
The following table describes the syntax for the omreport Battery commands
Table 74. Omreport Battery Commands
Required Command Levels (1, 2,
3)
Optional name=value pairs Use
omreport storage battery Displays all batteries present on
all controllers on the system
(Some controllers do not have
batteries).
controller=id, where id is the
controller number. For example:
controller=0
Displays the battery on the
specified controller.
controller=id battery=id, where
id is the controller number. For
example: controller=0
Displays the specified battery.
Omreport Global Information
The following table describes the syntax for the omreport Global Information commands.
Table 75. Omreport Global Information Commands
Required Command Levels (1,
2, 3)
Optional name=value pairs Use
omreport storage globalinfo
Displays whether smart thermal
shutdown is enabled or disabled.
For more information, see
Omconfig Global Enable Smart
Thermal Shutdown.
Displays the hot spare protection
policy that you have set. For more
information on setting hot spare
protection policy, see the Dell
139