Table 45. System Event Severity Parameters
Command Result Description
omconfig system events
type=<component name>
severity=info or omconfig
servermodule events
type=<component name>
severity=info
Enables notification for
informational, warning, and
critical events.
Least restrictive form of event
notification.
omconfig system events
type=<component name>
severity=warning or omconfig
servermodule events
type=<component name>
severity=warning
Enables notification for warning
and critical events.
Omits informational event
notification, for example, when a
component returns to normal
status.
omconfig system events
type=<component name>
severity=critical or omconfig
servermodule events
type=<component name>
severity=critical
Enables notification for critical
events only.
Restrictive form of event
notification.
omconfig system events
type=<component name>
severity=none or omconfig
servermodule events
type=<component name>
severity=none
Disables event notification. No event notification.
Index
Index refers to the number of an event for a particular component. Index is an optional parameter. When
you omit the index parameter, events are configured for all components of the specified type, such as all
fans. For example, when a system contains more than one fan, you can enable or disable event
notification for a particular fan. An example command is as follows:
omconfig system events type=fan index=0 severity=critical
or
omconfig servermodule events type=fan index=0 severity=critical
As a result of the example command, Server Administrator sends an SNMP trap only when the first fan in
the system chassis (index 0) has reached critical fan RPMs.
Omconfig System Webserver Or Omconfig Servermodule Webserver
Use the omconfig system webserver or omconfig servermodule webserver command to start or stop the
Web server. The following table displays the valid parameters for the command.