Command Line Interface Guide
name=Value Pair Description
false: Disables an individual platform event filter.
index=number Sets the index for the destination.
ipaddress=<ipv4 address
| ipv6 address | fqdn>
Sets the IP address for the destination.
NOTE: On 12G systems with iDRAC7 specific versions, ipaddress can
also be a Fully Qualified Domain Name (FQDN).
communitystr=text Sets the text string that acts as a password and is used to authenticate SNMP
messages sent between the BMC and the destination management station.
Omconfig System Platformevents Or Omconfig Servermodule
Platformevents
Use the omconfig system platformevents or omconfig servermodule platformevents command to
configure shutdown action, if any, taken for a specific platform event. You can also enable or disable
platform event filter alert generation.
CAUTION: If you set a platform event shutdown action to anything other than none or power
reduction, the system is forcefully shutdown when the specified event occurs. This shutdown is
initiated by firmware and is carried out without first shutting down the operating system or any of
the applications running on your system.
The following table displays the valid parameters for the command.
NOTE: Alert settings are mutually exclusive and you can set one at a time only. The action settings
are also mutually exclusive and you can set one at a time only. However, alert and action settings
are not mutually exclusive of each other.
Table 42. Parameters For Alert Action Command
Action Description
action=disable Disables the SNMP alert.
action=enable Enables the SNMP alert.
action=none Takes no action when the system is hung or has crashed.
action=powercycle Turns off the electrical power to the system, pauses, turns the power on, and
reboots the system.
action=poweroff Turns off the electrical power to the system.
action=powerreduc
tion
Reduces the processor speed until the power consumption comes down and
reaches below the warning threshold. If the system power consumption stays
below the warning threshold, increases the processor speed.
NOTE: This action is applicable only for PowerEdge Rack and Tower systems
earlier than PowerEdge 11G systems.
action=reboot Forces the operating system to shut down and initiates system startup, performs
BIOS checks, and reloads the operating system.
108