Command Line Interface Guide
Example Chassis Intrusion Actions
To clear all alert actions for chassis intrusion, type:
omconfig system alertaction event=intrusion clearall=true
or
omconfig servermodule alertaction event=intrusion clearall=true
Commands For Clearing Logs
You can use the omconfig system or omconfig servermodule command to clear the following logs: the
alert log, command log, and hardware or ESM log.
To clear the contents of the alert log, type:
omconfig system alertlog action=clear
or
omconfig servermodule alertlog action=clear
NOTE: Entering an invalid RAC user name may prevent the command log from displaying. Clearing
the command log resolves this condition.
To clear the contents of the command log, type:
omconfig system cmdlog action=clear
or
omconfig servermodule cmdlog action=clear
To clear the contents of the ESM log, type:
omconfig system esmlog action=clear
or
omconfig servermodule esmlog action=clear
NOTE: For more information about alert messages, see the Dell OpenManage Server Administrator
Messages Reference Guide at dell.com/support/manuals.
Omconfig System Pedestinations Or Omconfig Servermodule Pedestinations
Use the omconfig system pedestinations or omconfig servermodule pedestinations command to set IP
addresses for alert destinations.
The following table displays the valid parameters for the command.
NOTE: You can either specify the index and IP address as parameters together or you can set only
the community string as a parameter.
NOTE: Index 1 to 4 accepts an IPv4 address and index 5 to 8 accepts an IPv6 address. On 12G
systems with iDRAC7 specific versions, the index can accept IPv4, IPv6, or FQDN.
Table 41. Valid Parameters Of Omconfig System Pedestinations Or Omconfig Servermodule Pedestinations
name=Value Pair Description
destenable=true | false
true: Enables an individual platform event filter destination after a valid IP
address has been set.
107