Release Notes
recorded is reached, the existing oldest logs are overwritten. But for 11G servers or below,
when the maximum limit is reached, the information logging is stopped.
•
DF523827: On Citrix XenServer 6.0, if the Alert on Console alert action is configured from
the Server Administrator CLI or GUI, the alert message may not be displayed in a readable
format.
•
DF530134: On VMware ESX 4.1 managed node, while USB arbitration service is running,
Inventory Collector does not respond while stopping the Server Administrator services.
•
BITS099660: Server Administrator 4D4JN X00-00 remote node management does not
report LPe16002 #4V0JT cards in slots 3 and 4.
•
BITS112307: Server Administrator 7.4 does not consistently display DIMM failure
status.
•
BITS113585: Server Administrator does not log CPU or CMOS Battery Probe Alerts
and does not send SNMP traps.
•
BITS116474: On systems running XenServer6.1 operating system remote shutdown of
operating system does not work properly, if you clear the Shutdown OS first option.
•
BITS119516: DWS login fails on ESXi 5.5 with the latest SVN_704 build.
To resolve this issue, stop the USB arbitration service and run the Inventory Collector.
To stop the USB arbitration service:
1.
Run the “ps aux|grep usb” command to check if the USB arbitration service is running.
2.
Run the “chkconfig usbarbitrator off” command to prevent the USB arbitration service from starting during
boot.
3.
After the USB arbitrator service is stopped, reboot the server to allow the Inventory collector to run.
•
DF520449: On all versions of the ESX, the following USB connection error messages are
generated. These messages can be ignored.
The following is a typical message:
Vendor: iDRAC Model: MAS022 Rev: 1.00
Type: Direct-Access ANSI SCSI revision: 02
Vendor: iDRAC Model: SECUPD Rev: 0329
Type: Direct-Access ANSI SCSI revision: 02
(520449)
•
DF531509: The setup and/or system password configuration from Server Administrator
GUI or CLI is successful, but the password is displayed as blank instead of asterisk (*) on
the F2 BIOS page.
•
DF532055: From Windows Server 2008 R2 SP1, when an administrator manages Red Hat
Enterprise Linux 6.1 (64-bit) or 5.7 (32 and 64-bit) operating systems, Server Administrator
reports connection error intermittently.
Workaround: Perform the following and manage the remote system from webserver.
1.
Configure TCP Chimney offload to disable state by running following command:
netsh int tcp set global chimney=disabled
2.
Configure RSS (Receive Side Scaling) to disable state by running following command:
netsh int tcp set global rss=disabled