Software Support
Property Definition
• Ready — The power supply is functioning normally.
• Degraded — The power supply has encountered a failure and is
operating in a degraded state.
• Failed — The power supply has encountered a failure and is no
longer functioning. Storage Management is unable to communicate
with the enclosure using SES commands. The Failed state is
displayed when the enclosure does not respond to a status query
from Storage Management for any reason. For example, This state
is displayed when you disconnect the cable.
• Missing — The power supply is not present in the enclosure.
Part Number Displays the part number of the power supply.
This property is not displayed for the 22
x
S enclosures that have E.17
firmware or later.
Firmware Version Displays the firmware version number of the power supply. The firmware
version of power supply is available only in MD12XX boxes with enclosure
firmware version 1.04 and later.
Enclosure Temperature Probes
The enclosure temperature probes are displayed under the Temperatures object. You can select the Temperatures
object to view the status information. The status information includes the current temperature in Celsius and the
warning and failure thresholds for the temperature probe.
The failure threshold has a default value that cannot be changed. However, you can set the warning threshold.
Related Links
Temperature Probe Properties And Tasks
SMART Thermal Shutdown
Checking The Temperature Of The Enclosure
Setting The Temperature Probe Values
Setting The Temperature Probe Properties And Tasks
Click Set Temperature Probe to launch the wizard for changing the temperature probe’s Warning threshold. You can
change the Warning threshold for each of the temperature probes included in the enclosure.
To Launch The Set Temperature Probe Wizard
To launch the Set Temperature Probe wizard:
1. In the Server Administrator window, under the system tree, expand Storage to display the controller objects.
2. Expand a controller object.
3. Expand a connector object.
4. Expand the enclosure object.
5. Select the Temperatures object.
6. Click Set Temperature Probe.
Temperature Probe Properties And Tasks
Does my enclosure support this feature? See Supported Features. Use this window to view information about the
enclosure’s temperature probes.
96