Software Support
To Locate Set Reconstruct Rate In Storage Management
1. In the Server Administrator window, under the system tree, expand Storage to display the controller objects.
2. Select a controller object.
3. Click Information/Configuration on the controller Properties page.
4. Select Set Reconstruct Rate from the Available Tasks drop-down menu.
5. Select Execute.
You can also locate this task from the Change Controller Properties drop-down menu.
Related Links
Changing The Controller Properties
Setting The Redundant Path Configuration
Does my Controller Support This Feature? See Supported Features.
Redundant path is supported only on external PERC cards that use firmware version 6.1 and later. A redundant path
internal to the system is not supported. MD1xxx enclosures are supported.
For redundant paths, the enclosure must be in the Unified mode however specific port connections are not required. A
connection from either controller ports to either EMM In ports creates the redundant path as long as two cables are
used. But, Redundant Path continues to appear in the field even as the redundant path is removed. The redundant path
ceases to appear only when it is cleared in the storage management.
In a daisy-chain scenario, more than one enclosure can be connected to a controller in a redundant path mode. You can
connect up to three MD1000 and MD1120 to a PERC 6/E controller in a daisy-chain enclosure. You can connect up to four
MD1200 and MD1220 to a PERC H800 and PERC H810 controller in a daisy-chain enclosure. For an example of a daisy-
chain configuration (for PERC 6/E controller), see the following image:
If the communication channel between the connector and the first enclosure is lost, the redundant path configuration is
lost. In this case, the health of the logical connector is displayed as critical. Navigate to the Information/Configuration