Software Support
Alerts 2146 Through 2150 Received While Performing I/O, Consistency Check, Format, Or
Other Operation
If you receive alerts 2146 through 2150 while performing an operation other than a rebuild, replace the damaged disk
immediately to avoid data loss.
Perform the following steps:
1. Back up the degraded virtual disk to a fresh (unused) tape drive.
2. Replace the damaged disk.
3. Perform a rebuild.
Read And Write Operations Experience Problems
If the system hangs, times out, or experiences other problems with read and write operations, then there may be a
problem with the controller cables or a device.
Related Links
Cables Attached Correctly
Isolate Hardware Problems
A Task Menu Option Is Not Displayed
You may notice that the task menus do not always display the same task options. Some tasks are only valid for certain
types of objects or at certain times. For example, a Check Consistency task can only be performed on a redundant virtual
disk. Similarly, if a disk is already offline, the Offline task option is not displayed.
There may be other reasons why a task cannot be run at a certain time. For example, there may already be a task
running on the object that must complete before additional tasks can be run.
A Corrupt Disk Or Drive Message Suggests Running Autocheck During A Reboot
You can ignore the message and perform autocheck. The reboot completes after autocheck is completed. Depending on
the size of your system, it may take about 10 minutes.
Erroneous Status And Error Messages After A Windows Hibernation
Activating the Windows hibernation feature may cause Storage Management to display erroneous status information
and error messages. This problem resolves when the Windows operating system recovers from hibernation.
Storage Management May Delay Before Updating Temperature Probe Status
In order to display the enclosure temperature and temperature probe status, Storage Management polls the enclosure
firmware at regular intervals to obtain temperature and status information. On some enclosures, there is a short delay
before the enclosure firmware reports the current temperature and temperature probe status. This may cause a delay in
displaying the correct temperature and temperature probe status.
Related Links
Changing The Warning Threshold On The Temperature Probe