CacheCade Using Solid-State Drives
CacheCade is used to improve random read performance of the solid-state drive (SSD) based virtual disks. A solid-state
drive (SSD) is a data storage device that uses solid-state memory to store persistent data. SSDs significantly increase
the I/O performance (IOPS) and/or write speed in Mbps from a storage device. With storage controllers, you can create
a CacheCade using SSDs. The CacheCade is then used for better performance of the storage I/O operations. Use either
Serial Attached SCSI (SAS) SSDs or Serial Advanced Technology Attachment (SATA) SSDs to create a CacheCade.
Create a CacheCade with SSDs in the following scenarios:
• Maximum application performance — Create a CacheCade using SSDs to achieve higher performance without
wasted capacity.
• Maximum application performance and higher capacity — Create a CacheCade using SSDs to balance the
capacity of the CacheCade with high performance SSDs.
• Higher capacity — If you do not have empty slots for additional HDDs, use SSDs and create a CacheCade. This
reduces the number of HDDs required and increases application performance.
The CacheCade feature has the following restrictions:
• Only certified SSDs can be used to create a CacheCade.
• If you create a CacheCade using SSDs, the SSD properties are still retained. At a later time, you can use the SSD
to create virtual disks.
• A CacheCade can contain either SAS drives or SATA drives but not both.
• Each SSD in the CacheCade does not have to be of the same size. The CacheCade size is automatically
calculated as follows: CacheCade size =capacity of the smallest SSD * the number of SSDs. The unused portion
of SSD is wasted and cannot be used as an additional CacheCade or an SSD-based virtual disk.
• The total amount of cache pool with a CacheCade is 512GB. If you create a CacheCade which is greater than
512GB, the storage controller still uses only 512GB.
• The CacheCade is supported only on PERC H710P, PERC H800, and PERC H810 controllers with 1GB NVRAM.
• In a storage enclosure, the total number of logical devices including virtual disks and CacheCade(s) cannot
exceed 64.
NOTE: In order to use CacheCade for the virtual disk, the Write and Read policy of the HDD-based virtual disk must
be set to Write Back or Force Write Back and read policy must be set to Read Ahead or Adaptive Read Ahead.
Related Links
Managing The CacheCade
Managing The CacheCade
Ensure that SSDs are available in the storage enclosure before performing any CacheCade operations.
To create, resize, blink, or delete the CacheCade, go to the CacheCade(s) page:
The CacheCade(s) page is displayed.
1. In the Server Administrator window, under the System tree, expand Storage.
2. Click a storage controller. For example: PERC H710P Adapter.