Software Support
Controller Starting RAID Level Target RAID Level Comments
PERC 6/E, PERC 6/I, CERC
6/I, PERC H800 Adapter,
PERC H700 Adapter, PERC
H700 Integrated, and PERC
H700 Modular, PERC H310
Adapter, PERC H310 Mini
Monolithic, PERC H310 Mini
Blades, PERC H710 Adapter,
PERC H710 Mini Blades,
PERC H710 Mini Monolithic,
PERC H710P Adapter, PERC
H710P Mini Blades, PERC
H710P Mini Monolithic,
PERC H810 Adapter
RAID 0
RAID 1 Add a single disk
RAID 0 RAID 0, RAID 5 Add at least one additional
disk.
RAID 0 RAID 6 RAID 6 requires a minimum
of 4 disks.
Reconfiguration from RAID
0 to RAID 6 requires at least
2 additional disks even
when this exceeds the 4-
disk minimum required by
RAID 6
RAID 1 RAID 0 With or without adding
additional disks
RAID 1 RAID 5, RAID 6 Add at least one additional
disk.
RAID 6 requires a minimum
of 4 disks.
RAID 5 RAID 0 With or without adding
additional disks
RAID 5 RAID 5, RAID 6 Add at least one additional
disk.
RAID 6 requires a minimum
of 4 disks.
RAID 6 RAID 0, RAID 5 With or without adding
additional disks
RAID 6 RAID 6 Add at least one additional
disk
SAS 6/iR N/A N/A N/A
PERC S100, S110, and S300
RAID 0 RAID 0 With or without additional
disks
RAID 1 RAID 1 Without additional disks
RAID 5 RAID 5 With or without additional
disks
RAID 10 RAID 10 Without additional disks
Related Links
Choosing RAID Levels And Concatenation
Maintaining The Integrity Of Redundant Virtual Disks
Does my controller support this feature? See Supported Features.
The virtual disk Check Consistency task verifies the accuracy of the redundant (parity) information. This task only applies
to redundant virtual disks. When necessary, the Check Consistency task rebuilds the redundant data.
136