Path Health
The path health of the connectors is represented as normal, warning, or critical. The possible values are displayed as
Available, Degraded, or Failed.
If the enclosure health is displayed as degraded and further investigation shows all enclosure components (EMMs,
Fans, Physical Disks, Power Supplies, and Temperature) to be in normal condition, select the Information/Configuration
subtab of the enclosure to view details of the Path Failure.
Related Links
Setting The Redundant Path Configuration
Logical Connector Properties And Tasks
Clearing The Connectors Redundant Path View
If you do not want the redundant path view, physically disconnect the connector port from the enclosure and reboot the
system. After the system reboots, the user interface still displays the logical connector, but in a critical state. To clear
the redundant path mode, select Clear Redundant Path view from the Controller Tasks.
Selecting this option clears the redundant path view and the connectors are represented on the user interface as
Connector 0 and Connector 1.
Related Links
Setting The Redundant Path Configuration
Connector Components
For information on attached components, see Enclosure And Backplane Properties And Tasks.