SNMP Reference Guide
Table 1886. DRsPSUMonitoringCapable
Name
drsPSUMonitoringCapable
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.4
Description Defines the monitoring capabilities or the absence of a PSU in this location.
Syntax DellCMCPSUCapable
Access Read-only
Table 1887. DRsPSUVoltsReading
Name
drsPSUVoltsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.5
Description Defines the instantaneous PSU voltage reading.
Syntax DellPowerReading
Access Read-only
Table 1888. DRsPSUAmpsReading
Name
drsPSUAmpsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.6
Description Defines the instantaneous PSU current reading.
Syntax DellPowerReading
Access Read-only
Table 1889. DRsPSUWattsReading
Name
drsPSUWattsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.7
Description Defines the instantaneous PSU wattage reading.
Syntax DellPowerReading
Access Read-only
Chassis Servers
The following MIB tables provide server information for the chassis being monitored by the chassis management
controller.
Table 1890. DRsCMCServerTable
Name
drsCMCServerTable
Object ID 1.3.6.1.4.1.674.10892.2.5.1
Description Defines the CMC server table.
Syntax SEQUENCE OF DrsCMCServerTableEntry
Access Not-Accessible
506