SNMP Reference Guide
Description Defines the CMC power table.
Syntax SEQUENCE OF DrsCMCPowerTableEntry
Access Not-accessible
Table 1866. DRsCMC Power Table Entry
Name
drsCMCPowerTableEntry
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1
Description Defines the CMC power table entry.
Syntax DrsCMCPowerTableEntry
Access Not-accessible
Table 1867. DRsCMC PSUTable
Name
drsCMCPSUTable
Object ID 1.3.6.1.4.1.674.10892.2.4.2
Description Defines the CMC PSU table.
Syntax SEQUENCE OF DrsCMCPSUTableEntry
Access Not-accessible
Table 1868. DRsCMC PSUTableEntry
Name
drsCMCPSUTableEntry
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1
Description Defines the CMC PSU table entry.
Syntax DrsCMCPSUTableEntry
Access Not-accessible
CMC Power Information
The following MIB tables provide information on the chassis power.
Table 1869. DRsChassisIndex
Name
drsChassisIndex
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellCMCPowerIndexRange
Access Read-only
Table 1870. DRsPotentialPower
Name
drsPotentialPower
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.2
502