SNMP Reference Guide
Access Read-only
Table 1386. Agent Smart Thermal Shutdown
Name
agentSmartThermalShutdown
Object ID 1.3.6.1.4.1.674.10893.1.20.110.15
Description Indicates the status of smart thermal shutdown for PowerVault 220S and
PowerVault 221S enclosures.
Possible values:
1: Enabled
2: Disabled
3: Not applicable
Syntax Integer
Access Read-only
Physical Devices Group
The Physical Devices MIB group provides information about the devices managed by the Storage Management
software and their relationships to each other. The following MIB tables define objects and relationships (connections)
among the objects.
• Controller Table — describes available properties for each controller on the managed system.
• Channel Table — describes available properties for each channel on the managed system.
• Enclosure Table — describes available properties for each enclosure on the managed system.
• Array Disk Table — describes available properties for each physical array disk on the managed system.
• Array Disk Enclosure Connection Table — describes the connections between Fibre Channel array disks, their
enclosure, and their associated controller. For each object in the table, its
object number
corresponds to an
instance number in the appropriate MIB table for that object where all of the object properties can be found.
• Array Disk Channel Connection Table — describes the connections between SCSI array disks, their channel,
and their associated controller. For each object in the table, its
object number
corresponds to an instance
number in the appropriate MIB table for that object where all of the object properties can be found.
• Fan Table — describes available properties for each fan on the managed system.
• Fan Connection Table — describes the connection between each fan on the managed system and its enclosure.
Each
enclosure number
in the table corresponds to that enclosure instance in the Enclosure Table.
• Power Supply Table — describes available properties for each power supply on the managed system.
• Power Supply Connection Table — describes the connection between each power supply on the managed
system and its enclosure. Each
enclosure number
in the table corresponds to that enclosure instance in the
Enclosure Table.
• Temperature Probe Table — describes available properties for each temperature probe on the managed
system.
• Temperature Probe Connection Table — describes the connection between each temperature probe on the
managed system and its enclosure. Each
enclosure number
in the table corresponds to that enclosure instance
in the Enclosure Table.
• EMM Table — describes available properties for each Enclosure Management Module (EMM) on the managed
system.
• EMM Connection Table — describes the connection between each EMM on the managed system and its
enclosure. Each
enclosure number
in the table corresponds to that enclosure instance in the Enclosure Table.
• Battery Table — describes available properties for each controller battery on the managed system.
391