SNMP Reference Guide

Table 1345. BMC Serial Flow Control Type
Variable Name:DellBMCSerialFlowControlType
Data Type:Integer
Possible Data Values Meaning of Data Value
-- none(0)
No flow control used.
rtscts(1)
RTS/CTS (hardware) flow control
used.
xonXoff(2)
XON/XOFF flow control used.
Table 1346. BMC Serial Bit Rate Type
Variable Name:DellBMCSerialBitRateType
Data Type:Integer
Possible Data Values Meaning of Data Value
bps9600(6)
Bit rate is 9600 bps (bits per second)
bps19200(7)
Bit rate is 19200 bps
bps38400(8)
Bit rate is 38400 bps
bps57600(9)
Bit rate is 57600 bps
bps115200(10)
Bit rate is 115200 bps
Table 1347. BMC LAN IP Address Source Type
Variable Name:DellBMCLANIPAddressSourceType
Data Type:Integer
Possible Data Values Meaning of Data Value
-- unspecified(0)
Source is unspecified.
static(1)
IP address is static.
dhcp(2)
Dynamic Host Configuration Protocol
(DHCP) used to obtain IP address.
biosOrSystemSoftware(3)
BIOS or system software provided IP
Address.
other(4)
Other protocol used to obtain IP
address.
Table 1348. BMC Management Controller Type
Variable Name:DellManagementControllerType
Data Type:Integer
Possible Data Values Meaning of Data Value
-- legacyBMC(0)
Controller type is legacy Baseboard
Management Controller.
iDRAC(8)
Controller type is iDRAC.