Reference Guide
name=value pair 1
config=
name=value pair 2 Description
NOTE: This option requires license to enable or
disable ipv6. If the appropriate license is not
installed or has expired, the system displays an
error message. For more information, see
Dell
License Manager
at dell.com/
openmanagemanuals.
config=advsol characcuminterval=number
number: Sets the character accumulate interval in 5
millisecond intervals.
charsendthreshold=number
number: Sets the number of characters. BMC
automatically sends a serial over LAN data packet
that contains the number of characters as soon as
this number of characters (or greater) has been
accepted from the baseboard serial controller into the
BMC.
enableipmi= true | false
true: Enables IPMI over LAN.
false: Disables IPMI over LAN.
enablenic=true | false
true: Enables DRAC NIC.
false: Disables DRAC NIC
NOTE: The enablenic option is supported on
PowerEdge 9G systems that have DRAC 5
installed.
nicselection=sharedwithfailoveronall
| nic1 |teamednic1nic2 | dracnic
sharedwithfailoveronall: Configures the new NIC
selection option.
nic1: Enables NIC 1.
teamednic1nic2: Enables NIC teaming functionality.
dracnic: Enables DRAC NIC if DRAC 5 is installed.
NOTE: The nicselection option is supported only
on PowerEdge 9G to 11G systems. From
PowerEdge 12G systems onwards, primarynw
and failovernw replaces nicselection.
primarynw=dedicated | lom1 | lom2 |
lom3 | lom4
dedicated: Configures dedicated port as primary
network for remote access.
NOTE: This option requires license to configure
primarynw as dedicated. If the appropriate
license is not installed or has expired, the
system displays an error message. For more
information, see
Dell License Manager
at
dell.com/openmanagemanuals.
lom 1: Configures lom1 port as the primary network for
remote access.
lom 2: Configures lom2 port as the primary network for
remote access.
lom 3: Configures lom3 port as the primary network for
remote access.
lom 4: Configures lom4 port as the primary network for
remote access.
85