Reference Guide
or
omconfig mainsystem pwrmonitoring config=probe index=0 warnthresh=settodefault
You cannot default one value and set another. If you default the minimum warning threshold value, you are also
selecting the default value for the maximum warning threshold value.
Specify A Value For Warning Thresholds
If you prefer to specify values for the power consumption probe warning thresholds, you must specify the number of the
probe you are configuring and the warning threshold value. Configure the values to display either in BTU/hr or Watts. In
the following example, the probe that is being configured is probe 4:
omconfig chassis pwrmonitoring config=probe index=4 warnthresh=325 unit=watt
or
omconfig mainsystem pwrmonitoring config=probe index=4 warnthresh=325
unit=btuphr
When you issue the command and the system sets the values you specify, the following message is displayed:
Power consumption probe warning threshold(s) set successfully.
Omconfig Chassis Remoteaccess Or Omconfig Mainsystem Remoteaccess
Use the omconfig chassis remoteaccess or omconfig mainsystem remoteaccesscommand to configure:
• Remote access on a local area network (LAN).
• The serial port for BMC or RAC, whichever is installed.
• The BMC or RAC on a serial over LAN connection.
• Terminal settings for the serial port.
• Advanced settings for a serial over LAN connection.
• Information on a BMC or RAC user.
• Information on IPv6 and IPv4 interfaces.
NOTE: Enter the user ID to configure user information.
Type:
omconfig chassis remoteaccess
or
omconfig mainsystem remoteaccess
The output of the omconfig chassis remoteaccess or omconfig mainsystem remoteaccess command lists each of the
available configurations. The following table displays the valid parameters:
Table 30. Valid Parameters Of Omconfig Chassis Remoteaccess Or Omconfig Mainsystem Remoteaccess
name=value pair 1
config=
name=value pair 2 Description
config=additional ipv4=enable | disable
enable: IPv4 stack to load on iDRAC.
disable: IPv4 stack to flush on iDRAC.
ipv6=enable | disable
enable: Enables IPv6 stack to load on iDRAC.
disable: Disables IPv6 stack to unload on iDRAC.
84