Reference Guide

Valid Parameters For Fan Warning Thresholds
The following table shows the valid parameters for setting fan warning thresholds:
Table 23. omconfig chassis fans or omconfig chassis fans
name=value pair Description
index= <
n
> Number of the probe or probe index (must specify).
warnthresh=default Sets minimum and maximum warning thresholds to
default.
minwarnthresh=<
n
> Minimum warning threshold.
maxwarnthresh=<
n
> Maximum warning threshold.
Default Minimum And Maximum Warning Thresholds
NOTE: Systems that contain ESM3, ESM4, and BMC capabilities do not allow you to set warning threshold values
to default values.
To set both the upper and lower fan warning threshold values to the recommended default value, type:
omconfig chassis fans index=0 warnthresh=default
or
omconfig mainsystem fans index=0 warnthresh=default
You cannot default one value and set another. In other words, if you default the minimum warning threshold value, you
are also selecting the default value for the maximum warning threshold value.
Specifying A Value For Minimum And Maximum Warning Thresholds
If you prefer to specify values for the fan probe warning thresholds, you must specify the number of the probe you are
configuring and the minimum and/or maximum warning threshold values. In the following example, the probe that is
being configured is probe 0. The first command sets only the minimum threshold; the second sets the minimum and
maximum thresholds:
omconfig chassis fans index=0 minwarnthresh=4580
or
omconfig mainsystem fans index=0 minwarnthresh=4580
omconfig chassis fans index=0 minwarnthresh=4580 maxwarnthresh=9160
or
omconfig mainsystem fans index=0 minwarnthresh=4580 maxwarnthresh=9160
When you issue the command and the system sets the values you specify, the following message is displayed:
Fan probe warning threshold(s) set successfully.
NOTE: You cannot set the minimum and maximum warning thresholds for the fan probe on PowerEdge 9G system.
Omconfig Chassis Frontpanel Or Omconfig Mainsystem Frontpanel
Use the omconfig chassis frontpanel or omconfig mainsystem frontpanel command to:
configure the power button and the Nonmasking Interrupt (NMI) button
configure the LCD to display: