Reference Guide
Command
Level 1
Command Level
2
Command Level
3
User
Privilege
Required
Use
pedestinations P, A Sets IP addresses for alert destinations.
platformevents A Determines the shutdown action, if any, taken for a
specific platform event. Also, enables or disables
platform events filter alert generation.
recovery P, A Determines in advance how the system responds to a
hung operating system.
shutdown A Allows the administrator to select from several options
when shutting down the system.
thrmshutdown A Sets the severity level at which a thermal event
triggers a system shutdown.
webserver A Starts or stops the Web server.
chassis or
mainsystem
biossetup A Configures the behavior of specific system
components controlled by the BIOS.
fans P, A
Configures fan probe warning thresholds to the default
or a specific value.
NOTE: You cannot change threshold values on
embedded server management (ESM3) and Dell
PowerEdge
x8xx
systems.
frontpanel A Configures the Power button, Non-Masking Interrupt
(NMI) button, encryption access, and LCD display of
the system.
info P, A Allows you to set an initial value, or to edit the value of
the asset tag or chassis name.
leds P, A Specifies when to flash a chassis fault LED or chassis
identification LED, and allows you to clear the LED for
the system's hard drive.
memorymode A Enables or disables the spare bank, mirroring, raid, and
Double Device Data Correction (DDDC) memory modes,
and also specify which mode to use.
pwrmanagemen
t
P, A Allows you to choose between maximum power,
economy, and optimized performance of the system.
pwrmonitoring P, A Configures power consumption information and
thresholds.
remoteaccess A Configures remote access information.
temps P, A
Sets warning threshold values to the default or a
specific value.
58