Reference Guide
or
omconfig servermodule alertaction event=currentfail broadcast=true
Example Fan Probe Actions
To generate alerts when a fan probe detects a failure value, type:
omconfig system alertaction event=fanfail alert=true
or
omconfig servermodule alertaction event=fanfail alert=true
Example Chassis Intrusion Actions
To clear all alert actions for chassis intrusion, type:
omconfig system alertaction event=intrusion clearall=true
or
omconfig servermodule alertaction event=intrusion clearall=true
Commands For Clearing Logs
You can use the omconfig system or omconfig servermodule command to clear the following logs: the alert log,
command log, and hardware or ESM log.
To clear the contents of the alert log, type:
omconfig system alertlog action=clear
or
omconfig servermodule alertlog action=clear
NOTE: Entering an invalid RAC user name may prevent the command log from displaying. Clearing the command
log resolves this condition.
To clear the contents of the command log, type:
omconfig system cmdlog action=clear
or
omconfig servermodule cmdlog action=clear
To clear the contents of the ESM log, type:
omconfig system esmlog action=clear
or
omconfig servermodule esmlog action=clear
NOTE: For more information about alert messages, see the
Dell OpenManage Server Administrator Messages
Reference Guide
at dell.com/support/manuals.
Omconfig System Pedestinations Or Omconfig Servermodule Pedestinations
Use the omconfig system pedestinations or omconfig servermodule pedestinations command to set IP addresses for
alert destinations.
The following table displays the valid parameters for the command.
100