Command Line Interface Guide

Table 29. Valid Parameters Of Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoring
name=value pair 1 name=value pair 2 Description
index=<
n
> NA Number of the probe or probe index
(must specify).
config=probe warnthresh=settodefault Sets the minimum and maximum
warning thresholds values to default.
warnthresh=<
n
> Sets a value for the warning
threshold.
unit=watt | btuphr
watt: Displays the unit in Watts.
btuphr: Displays the unit in BTU/hr.
config=resetreading type=energy | peakpower
energy: Resets the system energy
reading.
peakpower: Resets the system peak
power.
NOTE: This command is applicable only on selected Dell 10G systems that support PMBus.
NOTE: Power monitoring requires license to configure the power budget information. If the appropriate license is
not installed or has expired, the system displays an error message. For more information, see
Dell License
Manager
at dell.com/openmanagemanuals.
Default Warning Thresholds
NOTE: Sensor managing capabilities vary across systems.
To set both the upper and lower power consumption probe warning threshold values to the recommended default value,
type:
omconfig chassis pwrmonitoring config=probe index=0 warnthresh=settodefault
or
omconfig mainsystem pwrmonitoring config=probe index=0 warnthresh=settodefault
You cannot default one value and set another. If you default the minimum warning threshold value, you are also
selecting the default value for the maximum warning threshold value.
Specify A Value For Warning Thresholds
If you prefer to specify values for the power consumption probe warning thresholds, you must specify the number of the
probe you are configuring and the warning threshold value. Configure the values to display either in BTU/hr or Watts. In
the following example, the probe that is being configured is probe 4:
omconfig chassis pwrmonitoring config=probe index=4 warnthresh=325 unit=watt
or
omconfig mainsystem pwrmonitoring config=probe index=4 warnthresh=325
unit=btuphr
When you issue the command and the system sets the values you specify, the following message is displayed:
Power consumption probe warning threshold(s) set successfully.
Omconfig Chassis Remoteaccess Or Omconfig Mainsystem Remoteaccess
Use the omconfig chassis remoteaccess or omconfig mainsystem remoteaccesscommand to configure: