Command Line Interface Guide

Table 22. BIOS Setup Settings On PowerEdge 12G Systems
Group name=value pair 1 attribute= name=value pair 2 setting=
BIOS Boot Settings attribute=BootSeq sequence=aliasname1, aliasname2,..... aliasnameN
attribute=HddSeq sequence=aliasname1, aliasname2,..... aliasnameN
Boot Settings attribute=BootMode setting=Bios | Uefi
attribute=BootSeqRetry setting=Enabled | Disabled
Embedded Server
Management
attribute=FrontLcd setting=None | UserDefined | ModelNum | Advanced
attribute=UserLcdStr setting=<
string
>
Integrated Devices attribute=EmbVideo setting=Enabled | Disabled
attribute=IntegratedNetwork1 setting=Enabled | DisabledOs
attribute=IntegratedNetwork2 setting=Enabled | DisabledOs
attribute=IntegratedRaid setting=Enabled | Disabled
attribute=IntegratedSas setting=Enabled | Disabled
attribute=InternalSdCard setting=On | Off
attribute=InternalSdCardRedundanc
y
setting=Mirror | Disabled
attribute=InternalUsb setting=On | Off
attribute=InternalUsb1 setting=On | Off
attribute=InternalUsb2 setting=On | Off
attribute=IoatEngine setting=Enabled | Disabled
attribute=OsWatchdogTimer setting=Enabled | Disabled
attribute=SriovGlobalEnable setting=Enabled | Disabled
attribute=UsbPorts setting=AllOn | OnlyBackPortsOn | AllOff
Memory Settings attribute=MemOpMode setting=OptimizerMode | SpareMode | MirrorMode |
AdvEccMode | SpareWithAdvEccMode
attribute=MemOpVoltage setting=AutoVolt | Volt15V
NOTE: Volt15V represents 1.5 Volt.
attribute=MemTest setting=Enabled | Disabled
attribute=NodeInterleave setting=Enabled | Disabled
attribute=SerialDbgOut setting=Enabled | Disabled
attribute=SysMemSize setting=<
string
>
attribute=SysMemSpeed setting=<
string
>
attribute=SysMemType setting=<
string
>
75