Command Line Interface Guide
The omreport system alertaction or omreport servermodule alertaction command is useful for
viewing
which alert
actions have been specified for components. To
set
an alert action for a component, use the omconfig system
alertaction or omconfig servermodule alertaction command. For more information, see omconfig: Managing Components
Using The Instrumentation Service.
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change
the user scripts as applicable.
NOTE: Due to the limitations of certain operating systems (for example, VMware ESXi), certain features are not
available with this release of OpenManage Server Administrator.
Components And Events Having View Alert Actions
View alert action properties for the following components and events, if the components or events are present on the
system:
• Battery Warning
• Battery Failure
• Chassis Intrusion
• Current Probe Warning
• Current Probe Failure
• Fan Warning
• Fan Failure
• Memory Pre-failure
• Memory Failure
• System Power Probe Warning
• System Power Probe Detects a Failure
• System Peak Power
• Power Supply Warning
• Power Supply Failure
• Degraded Redundancy
• Lost Redundancy
• Temperature Warning
• Temperature Failure
• Voltage Warning
• Voltage Failure
• Processor Warning
• Processor Failure
• Hardware Log Warning
• Hardware Log Full
• Watchdog Asr
• Storage System Warning
• Storage System Failure
• Storage Controller Warning
• Storage Controller Failure
• Physical Disk Warning
• Physical Disk Failure
46