Command Line Interface Guide
Omreport Chassis Slots Or Omreport Mainsystem Slots
Use the omreport chassis slots or omreport mainsystem slots command to view properties of the system’s slots. Type:
omreport chassis slots index=n
or
omreport mainsystem slots index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays properties for all of the
slots in the system. If you specify the index, Server Administrator displays properties for a specific slot.
NOTE: To maintain consistency across the commands, the output format of this command has changed. Change
the user scripts as applicable.
For each slot in the system, values display for the following fields given in the following table:
Table 13. Valid Parameters Of Omreport Chassis Slots Or Omreport Mainsystem Slots
Field Description
Index Number of the slot in the system.
Slot ID Silk screen name printed on the system's motherboard next to the slot. Alphanumeric text uniquely
identifies each slot in the system.
Adapter Name and/or type of the card that fits into the slot, for example, a storage array controller, SCSI adapter,
iDRAC Enterprise, or HBA.
Data Bus
Width
Width, in bits, of the information pathway between the components of a system. The range of the data
bus width is from 16 to 64 bits.
Omreport Chassis Temps Or Omreport Mainsystem Temps
Use the omreport chassis temps or omreport mainsystem temps command to view properties of the system’s
temperature probes. Type:
omreport chassis temps index=n
or
omreport mainsystem temps index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status,
readings, and thresholds set for any temperature probes that are present on the system. If you specify the index, Server
Administrator displays the summary for a specific temperature probe.
Omreport Chassis Volts Or Omreport Mainsystem Volts
Use the omreport chassis volts or omreport mainsystem volts command to view properties of the system’s voltage
probes. Type:
omreport chassis volts index=n
or
omreport mainsystem volts index=n
43